A chemical customer asks for the UN test report before approving your 3H1 jerrycan order, and the file holds a machine quotation, a resin data sheet and a photo of the mark. None answers the question the buyer is really asking: which design type was approved, and what proves this production lot still matches it. The decision is not whether the machine is UN certified, but which documents the container producer must hold and who issues each one.

The short answer: the design type is approved, the file proves the match

The machine is not UN-certified, and no machine builder can certify your container. The UN mark is issued for a packaging design type; the producer that makes and marks the 3H1 jerrycan holds the design-type test report, the marking allocation, the closure instructions and the batch records that tie each lot back to the tested design.

Six documents that belong in the file

Document packs differ by market and by the authority that authorizes the mark, but a 3H1 or 1H1 order rests on six records. Treat them as one chain: each answers a different question, and the missing link is what an incoming audit finds.

  • Design-type test report. Issued by the test laboratory or approval body, it names the packaging code, design type, material, dimensions and mass, closure, test conditions and results. Check that the drawing matches your mold.
  • Approval or mark allocation. The document from the competent authority that authorizes the mark and identifies the country code and manufacturer. The mark on the container must reproduce it.
  • Marking drawing. A controlled drawing showing where the seven mark elements sit, their character height and which cavity carries them. Operators check the first part against it.
  • Closure and liner instructions. The leakproofness result belongs to one tested closure and liner combination. Record supplier, part number, application torque and sealing surface, and give the filling line written instructions.
  • Batch production record. Resin grade and lot, regrind ratio, mold and cavity, machine settings, weight and wall checks, restart after interruption, and the marking applied. This ties a shipped pallet to the approved design.
  • Change and retest log. Every change to resin, mold, wall map, weight window, closure or process window is written down with date and decision. Where a change falls outside the design basis, the log shows the approval body was asked whether a retest is required.

The approval logic behind these records is set out inUN-marked jerrycan production, and the container-side stress behavior inHDPE container stress cracking.

Reading the mark: seven elements and three packing groups

The mark is short because every character carries information the file must match. Read it in order and check each element against the approval and the batch record.

  • The UN symbol, for packaging approved under the UN Model Regulations.
  • The packaging code, for example 3H1, 3H2, 1H1 or 1H2.
  • The performance level X, Y or Z, stating the packing groups the design passed for.
  • The relative density for solids, or the hydraulic test pressure in kPa for liquids. The two are not interchangeable.
  • The last two digits of the year of manufacture.
  • The two-letter code of the country that authorized the mark.
  • The manufacturer's name or registered code.
Packaging codes and performance levels. X covers packing groups I, II and III; Y covers II and III; Z covers III only. Confirm the exact code and mark layout with your competent authority and test laboratory.
Code or level What it identifies What the file must show
3H1Plastic jerrican, non-removable headThe tested design, closure and wall map
3H2Plastic jerrican, removable headA separate design type; not a 3H1 substitute
1H1Plastic drum, non-removable headThe drum design type, tested mass and stacking basis
1H2Plastic drum, removable headA separate design type with its own closure and test record
XPacking groups I, II and IIIThe approval states this level; the batch record supports it
YPacking groups II and IIIPacking group I goods sit outside this mark
ZPacking group III onlyPacking groups I and II goods sit outside this mark

Swipe the table to see all columns →

2L Plastic Bottle Blow Molding Machine | Four-Parison Extrusion and Bottle Take-Off A representative 2L plastic bottle blow molding machine with four-parison extrusion and bottle take-off. The machine, mold and configuration in your project may differ.

A file audit for one batch of 20 L 3H1 jerrycans

Take a batch of 20 L 3H1 jerrycans blown on a single-station machine. An auditor pulls a pallet and works backwards. The lot number on the carton leads to the batch record, which names the resin grade and lot, the regrind ratio, the mold and cavity, the machine settings, and the weight and wall checks. The same record names the mark applied. From there the auditor checks that the test report's packaging code, design type and closure are the ones in production.

The weak point is usually the change log. Suppose a new resin lot has a different melt flow, or the regrind ratio moves outside the design basis. The container may look identical yet sit outside the tested design. Record the change, stop marking the affected production, and ask the approval body whether a retest is needed before the mark goes back on.

The arithmetic is traceability. Count the containers on the pallet, divide by the number of cavities, and you get the cycles that produced them; the batch record should show a cycle count and weight checks in the same range.

What to send for a quotation

A machine quotation cannot replace the approval file, but it can be written so the file is easier to build. Send these with the enquiry:

  • Container drawing in 2D and 3D, including neck finish, handle, base and the intended wall map.
  • UN code (3H1, 3H2, 1H1 or 1H2), the dangerous goods UN number, packing group and any special provision.
  • The design-type test report or approval you already hold, and the laboratory or authority that issued it.
  • Resin grade, density, melt flow and the regrind ratio you intend to run.
  • Closure and liner specification, including the application torque your filling line uses.
  • Output target, cavity count, shift pattern, destination country and port.
  • Plant data: power supply, compressed air, cooling water and available floor space.

Send the drawing and approval documents through thecontact page, and compare the0.1-16 L single-station rangeor thedouble-station platformbefore fixing a model.

Source: E-SHION product data. Specifications are subject to change without notice; customization is available.