A mold quotation usually arrives with three confident lines: a million-shot guarantee, a named steel grade, a trial report on request. None of them is evidence. The buyer's real risk is not the mold price. It is a cavity that fails in month four, or a certificate whose heat number does not match the plate in the machine. Decide what you can verify on paper before the deposit leaves, and what needs a video walk-through.
What Should You Verify First in a Blow Mold Supplier?
Verify three documents before anything else: the steel mill certificate with a heat number that matches the mold plates, the heat-treatment record showing hardness and tempering for each cavity insert, and a trial report with measured wall thickness, cycle time and shot weight. Then confirm the same mold on video.
The Three Documents That Do the Real Work
A steel certificate is only useful when the heat number on the paper matches the heat number stamped or etched on the plate. Ask for the mill certificate, not a supplier-typed summary. On cavity inserts, check the grade and whether the certificate covers the block used for your mold or a generic stock batch.
Heat treatment is where a claimed hardness quietly disappears. A hardness value on a pre-hardened insert means little without the furnace record: tempering temperature, soak time and the readings taken afterwards. Ask for the record per insert, and compare the test points on the drawing with the points actually measured.
A trial report should carry the mold number, machine model, material grade, measured cycle time, shot weight, wall-thickness readings at marked points and photos of the first-off parts. A report that says only 'samples OK' and shows no numbers is a sales document, not a trial record.
Eight Documents to Request Before You Approve a Mold
Put the list inside the RFQ, so the supplier treats the file set as part of the order rather than a favour after the deposit. The eight items below cover steel, heat treatment, machining, fitting and the trial itself.
| Document | What it proves | What to check |
|---|---|---|
| Steel mill certificate | Plate grade and heat number | Heat number matches the plate marking; grade stated |
| Heat-treatment record | Hardness actually achieved | Furnace cycle, tempering temperature, post-temper readings |
| Cavity insert drawing | Final geometry and cooling layout | Revision matches the approved 3D model |
| Purchased-part list | What went into the tool | Blow pin, guide pin and bushing grades and brands |
| Machining inspection sheet | Dimensions after machining | Critical fits, parting-line flatness, guide-pin clearance |
| Mold trial report | Real performance of the tool | Measured cycle time, shot weight, wall thickness, cavity balance |
| First-off photos and dimensions | What the tool actually produced | Photos with scale, key dimensions, corrections listed |
| Spare-part and maintenance list | What you need to stay running | Recommended spares, seal and heater sizes, intervals |
Swipe the table to see all columns →
How Do You Write a Shot-Count Guarantee Into the Contract?
A shot guarantee is only enforceable when it defines the counting basis, the excluded causes and the remedy. A number written alone is marketing. Tie the guarantee to the cavity count, the material and the process window recorded in the trial, state whether shots are counted per cavity or per cycle, and list the wear parts it does not cover.
A workable clause reads: 'The mold is guaranteed for [agreed number] shots per cavity when run inside the process window recorded in the trial report, with the specified material and clamping force. The guarantee excludes damage from foreign objects, cooling water outside the agreed range, and unauthorised modification.' Fill the number only after the cavity layout and cycle are fixed.
Ask for a desensitised trial report from a comparable tool, same container size class and cavity count. Redaction still leaves the structure visible: whether cycle time, shot weight and wall thickness were measured at fixed points, or only photographs were kept. On a multi-cavity tool, compare the cavities with each other. One that runs consistently thinner points to a cooling or die-balance problem.
A mold is only half the purchase. The machine that clamps it sets the output ceiling, so check thesingle-station 0-16 L rangeor thedouble-station 0-16 L rangebefore fixing cavity count. Spare-part planning is covered inblow mold maintenance.
What to Send for a Quotation
A quotation can only be firm when mold and machine are specified together. Send these:
- Container drawing or 3D file with volume, neck finish and wall-thickness target.
- Cavity count you need now, and any count you may add later.
- Material grade and colour, including any regrind percentage.
- Machine model, or at least clamp force and platen size.
- Monthly or annual output target, so cycle time can be checked against capacity.
- The document set above, or the subset your supplier can actually provide.
- Destination country, because voltage, guarding and paperwork change the build.
Source: E-SHION product data. Specifications are subject to change without notice; customization is available.
This guide is written for production and procurement decisions. It uses published figures where available and avoids unverified performance claims.