A buyer comparing 5 L blow molding machines usually asks how many cavities the machine can run, then treats the number of die heads as the answer: two, three, four, maybe six. It is not. What caps cavity count in practice is die-head center distance, because every extra head pulls the pitch tighter while the container body stays the same width. Choose the head count before you check that pitch, and the mold may not close around the bottle you designed.
What Actually Limits Cavity Count on a Multi-Head Machine?
Die-head center distance sets the maximum container body diameter for a given head count. On the 0.1-16 L series, four heads sit closer together than three, and three closer than two: ES-5LS spacing drops from 160 mm to 110 mm to 85 mm. Fit the body, plus steel between cavities, inside that pitch.
Center distance is measured between the axes of two adjacent die heads. It is a mechanical property of the head block and the manifold that feeds it, so it cannot be adjusted on the shop floor. Two heads can use most of the platen width; a third head splits that width again, and a fourth splits it once more. The published figures do not scale neatly with model size, either. On the 0.1-16 L single-station range, ES-10LS carries a wider two-head spacing (280 mm) than ES-16LS (260 mm), even though the ES-16LS is the larger machine. Read the number for the model you are buying instead of assuming it grows with clamping force.
Once you have the pitch, the geometry is simple: container body diameter plus the steel you need between two cavities must fit inside the center distance. Neck spacing, blow-pin position, the pinch-off area and the take-off gripper all sit in the same block of space. That is why four heads are not automatically four times the output of one head. Either the bottles get narrower, or the head count comes down.
Published Die-Head Center Distance, Two to Four Heads
The table lists the published center distance for the 0.1-16 L single-station models at two, three and four heads, next to the extruder output range. Head count and plasticizing capacity have to be read together.
| Model | Two heads | Three heads | Four heads | Extruder output |
|---|---|---|---|---|
| ES-2LS | 120 mm | 90 mm | 65 mm | 50-55 kg/h |
| ES-5LS | 160 mm | 110 mm | 85 mm | 65-80 kg/h |
| ES-10LS | 280 mm | 160 mm | 120 mm | 80-100 kg/h |
| ES-16LS | 260 mm | 180 mm | 130 mm | 100-120 kg/h |
Swipe the table to see all columns →
Four heads on ES-5LS leave 85 mm between head axes, against 160 mm at two heads, a loss of 75 mm of pitch. Four heads on ES-10LS leave 120 mm, and four heads on ES-16LS leave 130 mm. Those numbers, not the head count itself, decide whether your bottle fits. A four-head ES-5LS and a two-head ES-5LS are the same machine frame with a different head block and a different set of molds.
Worked Example: When Four Heads Stop Fitting a 5 L Bottle
Take a 5 L container whose drawing shows a 100 mm body diameter, and assume the mold needs about 20 mm of steel between neighbouring cavities for cooling and strength. One pitch then needs roughly 120 mm. On ES-5LS, four heads give 85 mm, so that bottle does not fit; three heads give 110 mm, still short; two heads give 160 mm, which clears with room to spare. On ES-10LS, four heads give exactly 120 mm, so the bottle fits but with no margin, and the layout has to be checked cavity by cavity before the tool is cut. The same bottle that is impossible on a four-head ES-5LS is routine on a two-head ES-5LS or a four-head ES-10LS. Substituting your own body diameter and steel allowance gives the answer for your container, and a wider body only makes the gap worse.
Head count is only the first gate. The extruder has to plasticize enough melt for every parison in the cycle: four parisons per cycle need roughly four times the melt of one parison at the same cycle time, plus a margin for start-up and scrap. ES-5LS is published at 65-80 kg/h, ES-10LS at 80-100 kg/h and ES-16LS at 100-120 kg/h, so a four-head layout that the pitch allows can still be starved by the screw. Cooling is the second gate. More cavities share the same mold circuit and the same clamp, and the cycle usually stretches before it shortens.
Check the Extruder, Cooling and Clamp Before You Add a Head
- Melt: does the extruder output cover cavities x parison weight x cycles per hour, with headroom for scrap and start-up?
- Cooling: can the mold circuit pull heat out of every cavity at the cycle you actually need?
- Clamp: does clamping force cover the total mold projection area at your blowing pressure, not container volume alone?
- Take-off: can the gripper reach, release and drop every bottle at the tighter pitch?
- Mold cost: each cavity adds tooling, and a multi-cavity tool is quoted per layout, not per bottle.
The 0.1-16 L range is split by station count for a reason:single-station modelsanddouble-station modelsuse different head blocks, so the same head count does not give the same pitch. For small bottles, the1-2 L production notesare a useful cross-check.
What to Send for a Quotation
A cavity count quoted without the bottle drawing is a guess. Send these and the head count can be fixed against real geometry.
- Container drawing with body diameter, height, neck finish and weight. The body diameter is the number that decides head count.
- Target output in pieces per hour and the shift pattern you run.
- Material and layer structure, including any regrind percentage.
- Mold status: a new tool, an existing tool, or a tool to be re-laid out for a different head count.
- Blowing pressure, air supply and utilities available on site.
- Destination country and voltage, so the drive and control configuration is quoted correctly.
- A sample bottle if you can send one, so the pinch-off and neck area can be checked.
Still comparing models?Send the drawing through the contact pageand ask for the center distance of the exact model before you commit to a cavity count.
Source: E-SHION product data. Specifications are subject to change without notice; customization is available.
This guide is written for production and procurement decisions. It uses published figures where available and avoids unverified performance claims.